User manual
sinaCAM  Installation 
User Manual  Rev.: E  15 
7.4  Calculation of Maximum Cable Length 
The  maximum  cable  length  between  remote  camera  heads  and  base  unit  is limited  by  the  signal 
attenuation and the conductor DC resistance of the used cable type. 
Maximum cable length as limited by signal attenuation (rule of thumb): 
Max. cable length = 25 dB / attenuation at 1.5 GHz 
Maximum cable length as limited by conductor DC resistance (rule of thumb): 
Max. cable length = 8 Ω / conductor DC resistance 
Example calculation for Belden 1505F Flexible cable: 
–  Nom. attenuation at 1.5 GHz: 13.300 dB / 100 ft 
–  Nom. conductor DC resistance: 12.2 Ω / 1000 ft 
Max. cable length = 25 dB / (13.300 dB /100 ft) = ~188 ft (57 m) 
Max. cable length = 8 Ω / (12.2 Ω / 1000 ft) = ~656 ft (200 m) 
The lower of the two values determines the approximate maximum cable length, in this example 188 ft 
(57 m). 
7.5  Connecting the Hardware 
  Make sure that all hardware to be installed is switched off. 
  Connect all hardware to the base unit. 
  Switch on all hardware and the base unit. 