Installation Guide
Installing on Sloping Terrain
Caution: SimTek Fence is not engi-
neered for use as a retaining wall.
Installation on sloping terrain is similar to that on flat
terrain. Professionals typically use a laser to shoot
and obtain a grade.
1. Set the first post on the uphill side. Post
placement is important! Posts are typically
placed at the point where the slope changes,
whether in a peak or a valley.
2. The panel support brackets should be pre-
attached at 50" for 4ft, 74" for 6ft, and can
receive the down hill side of the panel at that
height. Once the slope and the drop per panel
have been determined, the bracket on the uphill
side should be adjusted to the proper height.
Panels will always be set level even on a slope.
3. Set the second post and make any adjustments
to bracket position.
4. Use a level on the stiener, placed between the
posts on the brackets, to ensure panels will be
level when installed.
5. For more information see illustration A and B.
A 6' wide panel can be stepped as much as 12" per panel. For steeper elevations you can
use our 142" long post. To reduce the gap under the panel, you can reduce the width of the
panel and add additional post. For more details and instructions call 1-866-648-9336.
Need Help? Call us at 1.866.648.9336
A
B
13
FYI
!
CAUTION