Installation manual

SimradMS70
The25cablesfromthetransducer(D)areconnectedtothethreetransceivershelves
(TRXU)inthetransceiver(B).AnEthernetswitchcontrollingtwolocalareanetworks
withinthetransceiverdistributetheprocessingtasksbetweenthesixbeamforming
computers(TRC).Theoperatorstationisconnectedtothesenetworksbymeansofan
Ethernetcable(1).
Systemunits
TheSimradMS70comprisesthefollowingunits:
Colourdisplay
MultibeamOperatorStation
TransceiverUnit
PowerSupplyUnits(3ea)
Transducer
MultibeamOperatorStation
TheMS70MultibeamOperatorStationisahighperformancecomputer.
ThecomputersoftwareisbasedonthecommercialMicrosoft
®
Windows
®
XP
®
operating
system.
TheMultibeamOperatorStationcommunicateswiththeEthernetswitchinthe
TransceiverUnitbymeansofanEthernetcable.
Thesoftwareontheoperatorstationprovidesyouwiththefollowingmainfunctionality:
OperationalcontroloftheSimradMS70
Communicationwithperipheralsensorsandoptionalpost-processingsystem(s)
Sonarpresentation
Menusystem
Contextsensitiveon-linehelp
TransceiverUnit
Thetransceiverperformsthesignalprocessinganddigitalbeamformingofthe
transmitterandreceiverchannels.
TheMS70TransceiverUnitishousedina19”instrumentrack.
Inordertoreducethelossinthetransducercables,thetransceiverisphysicallylocated
ascloseaspossibletothetransducerarray.
14