Specifications
Technicalspecications
TransceiverUnit
•Voltage
–Nominal:230V acsinglephase
–Deviation:15%ofnominalvoltage
–Transient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:600V A
•Frequency:47→63Hz
HullUnitSX92/93
•Voltage
–Nominal:230/380/440Vac3–phase,selectable
–Deviation:15%ofnominalvoltage
–Deviation,380/440Vac:340→485Vac
–Transient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:3000V A
•Frequency:47→63Hz
HullUnitSX95
•Voltage
–Nominal:230/380/440Vac3–phase,selectable
–Deviation:15%ofnominalvoltage
–Deviation,380/440Vac:340→485Vac
–Transient:20%ofnominalvoltage,recoverytime3s
•Powerconsumption:1100V A
•Frequency:47→63Hz
Weightsandoutlinedimensions
Thissectionprovidesthetechnicalspecicationsand
requirementsrelatedtoweightandoutlinedimensions.Formore
detailedinformationaboutthedimensions,refertoDrawingle
onpage26.
Note
Allweightsareapproximate.
ProcessorUnit
•Weight:15kg
•Width:452mm
•Height:269mm
•Depth:405mm
337432/A
21