Installation manual
Simrad SP90
76
851-164510 / Rev.E
C17 - Motor control
This cable is connected between the Transceiver Unit and the
Motor Control Unit mounted on the Hull Unit. Use the surplus
of cable C15, or an equivalent type of cable.
Observe the following procedure. To ensure correct operation,
tick off every item when the action has been carried out.
1 Use the cable gland on the left-hand side of the
Transceiver Unit.
2 Terminate the cable’s shielding in the cable gland.
Figure 2 1 Termination of cable
shielding
3 Terminate the seven cable pairs onto terminal block E201
in the Transceiver Unit.
- For the insulation of the shielding of each of the cable
pairs, use part of the supplied cable sleeve.
4 Run the cable from the Transceiver Unit to the Motor
Control Unit mounted on the gantry.
5 Use the cable gland on the right-hand side in the Motor
Control Unit, and terminate the cable shielding in the
cable gland.
6 Create a small cable slack inside the Motor Control Unit
as indicated in the Motor Control Unit illustration.
7 Make the E301 connections in the Motor Control Unit
according to the cable connection drawing.
- Note that the shielding of each cable pair shall not be
connected in the Motor Control Unit.