Installation manual

Cable layout
73
851-164510 / Rev.E
C8 / C9 - Operating panel (Power and serial)
This is a special dual cable from the Sonar Operating Panel to
the Sonar Processor Unit and the Sonar Interface Unit. This dual
cable has a common 15-pin Delta connector in the Sonar
Operating Panel end, a 9-pin female Delta connector in the
Sonar Processor Unit end (cable C8), and a 9-pin male Delta
connector in the Sonar Interface Unit end (cable C9). The cable
is included in the standard delivery, and the cable length is 4,5
meter.
Observe the following procedure for the connection of the panel
cable.
1 Connect the 15-pin Delta connector to the Operating
Panel.
2 Connect the 9-pin female Delta connector to the Serial A
connector on the rear side of the Sonar Processor Unit.
3 Connect the 9-pin male Delta connector to the J4
connector in the Sonar Interface Panel.
References
Sonar Operating Panel connections, page 72
Cable termination details (W625), page 201
C10 - Loudspeaker
This is a special cable for connections between the Loudspeaker
and the Sonar Interface Unit. The cable is included in the
standard delivery, and is pre-connected to the loudspeaker. The
cable length is 5 meters.
Observe the following procedure.
1 Mount the loudspeaker in an adequate position.
2 Connect the cable to the terminal TB8 in the Sonar
Interface Unit. The orange cable must be connected to
TB8-1 and the black cable to TB8-7.
References
Cable termination details (W208A), page 190