Installation manual

Cable layout
71
851-164510 / Rev.E
C5 - Sonar Interface Serial
This cable holds the serial line fed from the SP90 Sonar
Interface Unit to the SP90 Sonar Processor Unit. The cable is
pre-connected to the Sonar Interface Unit, and is equipped with
a special multi-connector in the Sonar Processor Unit end. The
cable length is 1.2 m.
1 Connect the plug to the connector on the circuit board in
slot J5 on the rear side of the Sonar Processor Unit.
References
Cable termination details (W206A), page 188
C6 - Cheapernet communication
This is the Cheapernet signal cable between the Sonar Processor
Unit and the Sonar Interface Unit. The cable is included in the
delivery, and it is terminated with BNC connectors in both ends.
The end with the T-connector must be connected to the Sonar
Processor Unit.
1 Connect the Cheapernet cable with the T-connector to the
BNC connector on the circuit board in slot J4 on the rear
side of the Sonar Processor Unit.
2 Connect the Cheapernet cable to the BNC connector J7 in
the Sonar Interface Unit.
References
Cable termination details (W206B), page 189