Installation manual
Introduction
23
851-164510 / Rev.E
Caution: If, for any reason, it is necessary to move the circuit
board or components from the conductive service mat,
they must be placed in an approved anti-static
transportation container (e.g. static shielding bag)
before transportation.
• During installation and servicing, all electrical equipment
(soldering irons, test equipment etc.) must be earthed.
Temperature protection
If the unit must be protected against extremes of temperature,
the carton/crate must be lined on all walls, base and lid with
5 cm thick polyurethane or polystyrene foam.
These units will be identified as delicate in the applicable
documentation.
The package must then be clearly marked:
Note: Must not be transported or stored in temperatures
below -5 degrees Celsius.
Other units can normally be stored in temperatures
between -30° C and +70° C, refer to the system’s technical
specifications for details.
Transducers must not be stored in temperatures below -20°C
and above +60°C.