12.2 Power specifications
SonarProcessorUnitMC70
Voltage:
- Nomin al: 115 / 230 Vac, single phase (selectable)
- Deviation: 15 % of nominal voltage
- Transient: 20 % of nominal voltage, recover time 3 s
Power consumption: 150 VA
Frequency: 47 to 63 Hz
Transceiver Unit
Voltage:
- Nomin al: 115 / 230 Vac, single phase (automatic)
- Deviation: 15 % of nominal voltage
- Transient: 20 % of nominal voltage, recover time 3 s
Power consumption: 600 VA
Frequency: 47 to 63 Hz
Hull Unit
Voltage:
- Nomin al: 230 / 380 / 440 Vac, 3-phase (selectable)
- Deviation, 230 Vac: 15 % of nominal voltage
- Deviation, 380 / 440 Vac: 340 to 485 Vac
- Transient: 20 % of nominal voltage, recover time 3 s
Frequency: 47 to 63 Hz
Power consumption: 3000 VA max
Sonar Interface Unit
Not applicable.
Display Unit
Refer to the documentation for the applicable unit.