Installation manual

Final tests and measurements
157
851-164510 / Rev.E
8 Enter the measured hydrophone voltage U(p-p) into the
Measurement and calculation results table, and calculate
the U Hydr voltage in the same table.
Refer to table 6.
Measurements/calculations Value Unit Example
Noise level dB --25.2
Hydrophone voltage U(p--p) volt 0.8
U(RMS) = U(p--p)/22 volt 0.28
U Hydr = 20 log U(RMS) dB//1V --10.9
Table 6 Measurement and calculation results
9 Make the requisite calculations in the Measurement and
calculation results table, and enter the result into the
Receiving voltage response (VR) table.
The Receiving voltage re sponse (VR) table is shown as
table 7.
10 Retrieve the Hydrophone sensitivity as transmitter S
from the Test hydrophone data table.
The Test hydrophone data table is shown as table 3 on
page 151 (Source level measurements).
11 Enter the data into the Receiving voltage response (VR)
table.
12 Retrieve the 20 log r value from the Measurements
results table.
The Measurements results table is shown as table 4 on
page 154 (Source level measurements).
13 Enter the data into the Receiving voltage response (VR)
table.
VR = ÷(S + U Hydr ÷ 20 log r)
Data Value Unit Example
S = S Hydrophone
dB//µPa/V
119.2
U Hydrophone dB//1V --10.9
20 log r dB 17.5
VR (Voltage Response)
dB//1V/µPa
--90.8
Table 7 Receiving voltage response (VR)
14 Calculate the voltage response with the formula given in
Receiving voltage response (VR) table.
Expected receiving voltage response is approximately:
VR = -90 ±3 dB//1V/µPa