Installation manual

Final tests and measurements
153
851-164510 / Rev.E
6 Enter the result into the Measurements results table.
The Measurement results table is shown as table 4 on
page 154.
7 Read the peak-to-peak value of the transmitter pulse
U(p-p).
8 Enter the results into the Measurements results table.
The Measurement results table is shown as table 4 on
page 154.
9 Access the Horizontal menu.
10 Push the Ping Sector button, and observe the Ping Sector
submenu appear at the bottom of the menu field.
11 Select Sector.
12 Read the oscilloscope measurements, and use the manual
training controls on the Operating Panel to obtain
maximum possible hydrophone voltage.
13 Enter the bearing angle, tilt angle, depth and water
temperature into the Measurements results table below.
Refer to table 4.
14 Make the requisite calculations in the Measurements
results table.
The Measurement results table is shown as table 4.
15 Enter the 20 log r and U Hydr. values from the
Measurements results table into the Source Level (SL)
table.
The Source Level (SL) table is shown as table 5.