11.2 Source level (SL) measurements
Preparations
The procedure calls for a test hydrophone. Prior to use, fill in
the technical specifications and the appropriate environmental
specifications for the hydrophone to be used. Use the table
provided.
Refer to table 3
Hydrophone data
Value Unit Example
Serial number Serial No. 1823860
Date of calibration* month/year 10/96
Calibrated at temperature °C 18°
Sensitivity as transmitter S dB//1µPa/V 119.2
Sensitivity as receiver M dB//1V/µPa --208.9
M e xtension cable (0.7/10m) dB//1V/µPa 0.7
M total = M + M extension dB//1V/µPa --209.6
Table 3 Test hydrophone data
Finally, you need to hook up the test equipement.
Refer to figure 42 for the necessary test schematics.
Preparing the operational mode
For measurement of the source level in omni mode, use the
following menu settings.
1 Select the Setup menu.
2 Press the Test... button to access up the System Text
menu.
3 Press the Test Config button.
4 Observe the Test Config submenu appear in the bottom
part of the menu field.
5 Select Source Level.
This command sequence has now automatically set up all the
sonar parameters required to do the source level measurements.