Installation manual
Testing the peripheral equipment
143
851-164510 / Rev.E
Heading data from (D)GPS
If the GPS is used for the course gyro input, wait with this test
until the GPS position data are tested.
Use the following procedure for testing the GPS input:
1 Access the I/O Setup menu.
2 Select Sensors in the I/O Setup menu, then Heading and
finally Gyro.
3 Observe the Sensor Config submenu appears at the
bottom of the menu field.
4 Change the settings in the Sensor Config submenu to suit
your requirements for the serial line.
5 Press Close to exit the Sensor Config menu.
6 Check that the heading readout in the Status menu
corresponds to the GPS heading.
Related topics
→ I/O Setup procedure, page 137.