Installation manual

Simrad SP90
124
851-164510 / Rev.E
5 Check that the following small LEDs on the Transceiver
Interface Board (TIB) illuminate (refer to the indication
on the front of the power supply):
- +8 V, -8 V, +5VA, -5 AV, +5 V, +12 V, +24 V and +24
Vstand-by.
6 Switch off the Transceiver Unit by setting the service
switch S202 on the power supply to the Normal position.
7 Start up the sonar in the wheelhouse by pressing the
Power button on the Operating Panel for approximately
two seconds.
8 Check that the Transceiver Unit starts up after
approximately two minutes, and the two LEDs marked
COM on the top of the SPB-31 circuit board starts to
flash.
9 Switch off the sonar, and check that the Transceiver Unit
is switched off as well.
References
S301 in the Motor Control Unit, page 104
Connecting C15, page 101
Location of COM and TXEN. LEDs, page 129