Installation manual

Simrad SP90
110
851-164510 / Rev.E
Display set-up
Observe the following procedure to set up the display and
retrieve simulated sonar echoes.
1 Refer to the instruction manual for the display unit, and
adjust the picture size so the grey picture frame is shown
in the outmost part of the display frame.
2 Use the trackball and the Select button on the Operating
Panel, and observe this procedure to obtain a simulated
echo on the screen.
a Move the cursor to the Setup tabontheright-handside
of the main menu, and press the Select button.
-TheSetup menu will be displayed.
b Move the cursor to the Test... buttonintheSetup
menu, and press Select.
-TheSystem test menu will now appear in the menu
field.
c Move the cursor to the Installation Menu button and
press Select.
-TheInstallation menu will now appear on the top
of the screen.
d Move the cursor to Simulation and press the Select
button. Select Modes and then Auto.
3 Check that simulated echoes are displayed on the screen
after a few seconds.
- If not, check that the tilt angle in the upper left-hand
corner is set to 0 degrees.