Installation manual
Cable layout and connections
67
851-164574 / C
2 Terminate the cable shielding.
→ Cable shielding is shown in figure 23.
Cable
main
screen
(CD3117)
Figure 23 Termination of
cable shielding
3 Terminate the seven cable pairs onto terminal block E201 in
the Transceiver Unit.
- For the insulation of the shielding of each of the cable
pairs, use part of the supplied cable sleeve.
→ Refer to the cable connection drawing on page 180 for
termination details for E201.
4 Run the cable from the Transceiver Unit to the Motor
Control Unit mounted on the gantry.
5 Use the cable gland on the right-hand side in t he Motor
Control Unit, and terminate the cable shielding in the cable
gland.
→ The cable shielding is described in figure 23 on page 67.
→ The interior of the Motor Control Unit is s hown in figure
24.
6 Create a small cable slack inside the Motor Control Unit as
indicated in the figure.
7 Make the E301 connections in the Motor Control Unit
according to the cable connection drawing.
- Note that the shielding of each cable pair shall not be
connected in the Motor Control Unit.
→ Refer to the cable connection drawing on page 180.