Installation manual

Cable layout and connections
65
851-164574 / C
C10 - Loudspeaker
This is a special cable for connections between the Loudspeaker
and the Sonar Interface Unit. The cable is included in the standard
delivery, and is pre-connected to the loudspeaker. The cable length
is 5 meters.
Cable details on page 175.
Observe the following procedure.
1 Mount the loudspeaker in an adequate position.
2 Connect the cable to the terminal TB8 in the Sonar Interface
Unit. The orange cable must be connected to TB8- 1 and the
black cable to TB8-7.
C15 - Transceiver Unit
This is a data cable fr o m the Sonar Interface Unit in the wheelhouse
to the Transceiver Unit in the sonar room. The cable is included in
the standard delivery with a l ength of 100 meters, and it has a
pre-connected plug in the Sonar Interface Unit end.
Cable details on page 178.
1 Run the 100 m data cable from the wheelhouse to the sonar
room.
- Note that the pre-connected plug will be connected to the
Sonar Interface Unit in the wheelhouse at a later stage.
Note The data cable from the wheelhouse to the sonar room must be
supported and protected along its entire length using conduit
and/or cable trays. The cable must not be installed in close
proximity to high-power cables antenna cables or other possible
sources of interference.
This cable must not be spliced. If it is not long enough, or if an
accident occurs to it, contact your local dealer or Simrad for
advice.
2 Do not connect the plug to the Sonar Interface Unit.
The i nstallation of this cable into the Transceiver Unit is
described on page 68.