Installation manual

Cable layout and connections
63
851-164574 / C
2 Secure the plug on the rear side of the Sonar Processor Unit
with the bracket.
If the delivered cable connector does not fit, replace it with a
suitable connector.
C4 - Sonar Interface Control
This are the control signals between the Sonar Processor Unit and
the Sonar Interface Unit. The cable is pre-connected to the Sonar
Interface Unit, and i s equipped with a 37-pin female Delta
connector in the Sonar Processor Unit end. The cable length is 1.2
m.
1 Connect the plug to the connector on the far right hand side
of the Sonar Processor Unit.
Cable details on page 173.
C5 - Sonar Interface Serial
This is the serial lines fed from the Sonar Interface Unit to the
Sonar Processor Unit. The cable is pre-connected to the Sonar
Interface Unit, and is equipped with a special multi-connector in
the Sonar Processor Unit end. The cable length is 1.2 m.
1 Connect the plug to t he connector on the circuit board in slot
J5 on the rear side of the Sonar Processor Unit.
Cable details on page 173.
C6 - Cheapernet communication
This is the Cheapernet signal cable between the Sonar Processor
Unit and the Sonar Interface Unit. The cable is included in the
delivery, and it is terminated with BNC connectors in both ends.
The end with the T-connector must be connected to the Sonar
Processor Unit.
1 Connect the Cheapernet cable with the T-connector to the
BNC connector on the circuit board in slot J4 on the rear side
of the Sonar Processor Unit.
2 Connect the Cheapernet cable to the BNC connector J7 in
the Sonar Interface Unit.
Cable details on page 174.
C7
- Operating panel (USB)
This is a standard USB data cable. It connects between the
Operating Panel and the Processor Unit. The cable is included in
the standard delivery, and the cable length is 4, 5 meters. The cable
has a quadratic USB connector in the Operating Panel end, and
rectangular USB connector in the Processor Unit end.