Installation manual

Cable layout and connections
59
851-164574 / C
C11-C14 / C20-C25 Peripheral equipment
These are cables used to interface peripheral equipment. They are
described in detail in chapter Peripheral equipment.
See page 75.
C15 - Transceiver Unit
This is a data cable fr o m the Sonar Interface Unit in the wheelhouse
to the Transceiver Unit in the sonar room. The cable is provided
by Simrad.
Cable details on page 178.
C16 - Transducer cable
The transducer cables are provided by the manufacturer. They are
physically connected to the top of the transducer shaft. All
transducer cables are provided by Simrad.
C17 - Motor control
This cable is connected between the Transceiver Unit and the
Motor Control Unit mounted on the Hull Unit.
Cable details on page 180.
Note that the physical properties of this cable is identical to those
of C15. Therefore, any surplus of the C15 cable can be used.
C19 - Motor control mains
This cable provides AC mains to the Motor Control Unit. The cable
must be provided by the installation shipyard.
Cable details on page 182.