Installation manual
Simrad SP60
130
851-164574 / C
10.4 Course gyro
Introduction
The heading can come from two different sensor types. Tick off for
the type which will be connected.
• Course gyro
• (D)GPS
Note that the heading information from a GPS is generally too
inconsistent to provide a stable sonar presentation.
Refer to the selected heading source in the f ollowing text.
Course gyro
The Processor Unit can read the heading information from a
RS-232 serial line. If only a 3-phase synchro or stepper signal is
available, an optional gyro interface unit must be used for
converting these signals to RS-232 serial line format.
Observe the fo llowing procedure to test the course gyro input:
1 Access the I/O Setup menu.
2 Select Sensors in the I/O Setup menu, then Heading and
finally Gyro.
3 Observe the Sensor Config submenu appears at the bottom
of the menu field.
4 Change the settings in the Sensor Config submenu to suit
your requirements for the serial line.
5 Press Close to exit the Sensor Config menu.
6 Check that the heading readout in the Status menu
corresponds to the vessel’s course gyro.
Related topics
→ Course gyro information, page 6.
→ I/O Setup procedure, page 125.
Heading data from (D)GPS
If the GPS is used for the course gyro input, wait with this test until
the GPS position data are tested.
Use the following procedure for testing the GPS input:
1 Access the I/O Setup menu.
2 Select Sensors in the I/O Setup menu, then Heading and
finally Gyro.