Installation manual
Start-up procedures
93
851-164574 / C
(CD6243C)
Upper limit
switch S304
Lower limit
switch S305
Motor Control
Unit
Hoist motor
Hand crank
Figure 32 Location of the brake
release screw, positioning the
hand crank for manual hoisting
13 Activate the lowering contactor K302 by setting the
hoisting/lowering switch S302 to Lower position, and check
if the contactor is deactivated when pressing the lower limit
switch S305 downwards.
14 Set the hoisting/lowering switch S302 to Stop position.
Apply 3-phase AC power
You will now apply 3-phase mains power to the hull unit.
1 Reinsert the 3-phasemains fuses for the hull unit in the ship’s
fusebox.