Installation manual

Simrad SP60
90
851-164574 / C
4 Measure the mains voltage supplied to the Transceiver Unit.
- Write down the measured voltage here:
Supply voltage (Vac):
5 Check that the voltage selector switches, S201 on the power
supply and S203 on the HV power unit, correspond to the
measured voltage (115 Vac or 230 Vac position).
6 Reinsert the mains input connector P201 on the front of the
power supply.
7 Check that lamps L201 and L202 on the front of the power
supply illuminate.
8 Check that the small LED (Light Emitting Diode) for the
+24 Vdc stand-by power on the Transceiver Interface Board
(TIB) illuminates.
- Refer to the indicator on the front of the power supply.
The +24 Vdc stand-by power is now supplied both to the Hull Unit
and to the connector for the Sonar Interface Unit.