Installation manual
Simrad SP60
6
850-164575 / Rev.D
Options
General
The standard SP60 sonar is a single 26 kHz version with beam
stabilization.
The beam stabilization was an optional function until 1 January
2003. After that date, the function was included with the
standard sonar delivery.
The options described below are pre-programmed into the
standard software version, and a code word is required to make
the actual option available. Simrad offers a 1 month free test
period for certain options. Note that the Scientific Output
function is not available for such a test period.
For a permanent installation of a chosen option, a new code
word will be released from Simrad when the option is ordered.
Triple- or multiple-frequency
In addition to the standard 26 kHz frequency, options are
available for triple and multiple frequencies.
In the triple-frequency version, you can select between 24
kHz, 26 kHz and 28 kHz.
In the multiple-frequency version you can select from 11
frequenciesfrom20to30kHzin1kHzsteps.
These selections are particulary useful when it is necessary to
suppress interference from other sonars.
Scientific output
The Scientific Output is designed for research purposes. When
activated, the following data are available on an Ethernet (LAN)
output:
Beam data
Target data
Own ship data
Gear data
The scientific output option may also include software for a
Scientific Data Logger.
Note that this option is not available for a free test period.
Related topics
Code words, procedure, page 53