Installation manual
Simrad SP270
24
851-160572 / B
Cable
main
screen
(CD3117 / GIF)
Figure 16 Termination of
the cable main screen
Note that the mains power connection to the Transceiver Unit
can be 115 VAC or 230 VAC. Use the following procedure for
the connection of the mains power:
1 Pull out the mains input connector P201 on the power
supply in the Transceiver Unit. For location of the
connector, refer to figure 17.
2 Set the mains voltage selector switch S201 on the Power
Supply and S203 on the HV Power Unit to correspond to
the correct mains voltage (115V or 230V), and replace the
switch lock to secure the switch in the correct position.
3 Set the service switch S202 on the Power Supply to OFF
(middle) position.
4 The mains power cable (3) may be connected to a normal
mains outlet in the sonar room. If the delivered cable
connector does not fit, put on a suitable connector.
5Donotmount the flexible transducer cables to the
Transceiver Unit.