Specifications
IS15 General Manual
68 20220760L
Securing the connectors
It is recommended that for extra security you secure the
connectors with the enclosed self-tapping screws.
Figure 6-7 Securing connectors to the instrument
Make sure that all empty sockets have the protection plugs
inserted. Coat the connectors with silicone grease or petroleum
jelly. These products will not harm the instrument.
6.7 Instrument head connections
Figure 6-8 - Instrument Connections
The instrument head has four identical two-pin connector sockets
protected by rubber plugs. Each socket is identified by number
and signal markings.
Caution ! NMEA cable must be plugged into connector no. 4. Wrong
connection may damage the connected equipment.