Specifications

Fault Finding
20220760L 109
Condition Probable Cause Action
The Wind Speed has
always been too low
or too high.
The wind transducer
may be poorly sited.
Check the transducer location.
Contact your dealer.
The Wind Angle
displays are
incorrect.
The wind transducer is
not connected to the
IS15 Transceiver
properly.
Check the wind transducer’s connections
to the IS15 Transceiver and to the Junction
Box.
Check that the wind transducer cable is not
damaged.
Contact your dealer.
The Wind Angle has
always been
incorrect.
The wind transducer is
not calibrated.
Calibrate the wind transducer. (Using
another instrument.)
Make checks as for ‘the wind angle
displays are incorrect’ above.
Note ! A broken vane can only be replaced by the factory, as the Masthead Unit
(MHU) needs new calibration.