Installation and Calibration Menu
The installation menu is arranged as follows:
Screen
Display
Screen 1
Screen 2
Screen 3
Screen 4
Screen 5
Digital
Illumination
bank
bAn.1
Compass
Calibration
CAL.C
Heading Offset
OFFS
Heading T/M
HdG
Shop mode
(on/off)
SHOP
Screen
Display
Screen 6
Screen 7
Screen 8
Screen 9
Screen 10
Digital
NMEA In/out
N 183
Roblink on/off
robl
Test display
tESt
Communication
reset
CrES.
Master reset
rES.
To enter Installation Menu:
1. Press the
button and hold for 10 seconds to access the
Installation Menu.
2. Apply a short press on the
or button to select one of
the LCD screens in the Installation Menu.
3. Press the
button, hold for 2 seconds and release to access
a setting. The item to be set starts flashing.
4. Apply a short press on the
or button to select a new
setting.
5. Press the
button and hold for 2 seconds to save a setting.
6. Apply a short press on the
button to show the next screen
or
press the button and hold for 2 seconds to return to
normal operation.
Screen 1
ILLUM. BANK [bAn.1]
The display reads bAn.0 bAn.2
The IS15 instrument system can have two separate banks of
instruments. Setting the lighting level on one display will set all
the other displays in that bank to the same level, but will not
effect any displays in the other bank. For instance, the lighting
level can be independently controlled for:
The cockpit and chart table displays of a yacht.
The cockpit and mast displays of a yacht.
The cabin and fly bridge of a power boat.