Installation manual

On-board maintenance
Whenever required
1 Apply lubrication. Refer to Air bleeding on page 198.
Wheelhouse units
Observe the following on-board maintenance instructions for the
units installed in the wheelhouse.
Colour display
Observe the following on-board maintenance instructions for the
colour display. For detailed maintenance instructions, observe
the information provided in the display documentation.
Display cleaning
The colour display must be kept clean and dry. Remove dust and
salt water residue with a soft cloth moistened in fresh water. D
o
not use strong solvents.
Note
The display screen must be handled with care to avoid damage
to the anti-glare lter coating.
Dedicated cleaning chemicals for CRT and LCD displays are
provided by ofce suppliers.
APC10 Processor Unit
Observe the following on-board maintenance instructions for the
APC10 Processor Unit.
APC10 cleaning
The APC10 Processing Unit must be kept clean and dry. Remove
dust and salt water residue with a soft cloth moistened in fresh
water. D
o not use strong solvents.
APC10 dust lter
To avoid overheating, the dust lter(s) must be inspected, and if
necessary, cleaned once every third month. The dust lter on
the APC10 is located on the air inlet on the rear side of the unit.
Replace the dust lter if required.
164385/E 181