Installation manual

Parameters
Range
The Range parameter dialogue opens when you click the Range
button in the Horizontal and Vertical menus.
Horizontal and vertical ranges are normally selected using the
buttons on the Operating Panel. You can also control these
settings directly using this parameter dialogue. The available
choices are listed in the dialogue. In addition to the read-out on
the menu, the current horizontal range is normally displayed over
the tilt indicator in the upper, left-hand corner of the display.
Available ranges are 50, 75, 100, 150, 200, 300, 400, 500, 600,
750, 1000, 1200, 1500 and 2000 meters.
Options
[Range]: Click to select manual r ange.
Manual: Click to enable manual range selection.
Auto: Click to enable automatic range selection during position-
and target tracking. This allows for optimal tracking.
Close: Click to close the parameter dialogue.
Help: Click to access the on-line help.
To maintain a steady display during seine setting, the lower
automatic range is set to 450 meters. C hanging the range or
pressing the
Manual button will stop the automatic ranging
function.
The sonar is designed to work with various horizontal range units
such as meter, nautical mile, US survey feet or yards. This choice
can be made by pressing the
Units button in the Display menu.
Related topics
Horizontal menu on page 79
Vertical menu on page 81
Operating P anel Range eld on pa
ge 69
164385/E
141