Installation manual

Simrad SH80
66
851--164300 / C
Figure 24 Connections to
the Motor Control Unit
C19
C17
REMOTE
S 302
HOIST STOP
LOWER
HAND CRANK
S 303
(CD5821)
Cable
strip
E301
S302
Hand
crank
(S303)
S301
Refer to the cable connection drawing on page 163.
C15 - Sonar Interface Unit
This is the control and data cable from the Processor Unit in the
wheelhouse to the Transceiver Unit in the sonar room. The cable
is included in the standard delivery, with a length of 100 meters.
Note Cable C17 from the Transceiver Unit to the Motor Control Unit
must be connected before
cable C15. This is necessary because the
wires in cable C17 are connected to the bottom row of terminal
E201.