Installation manual
Cable layout and connections
65
851--164300 / C
2 Terminate the cable shielding.
→ Cable s hielding is shown in figure 23.
Cable
main
screen
(CD3117)
Figure 23 Termination of
cable shielding
3 Terminate the cable pairs onto terminal block E201 in the
Transceiver Unit.
- For the insulation of the shielding of each of the cable
pairs, use part of the supplied cable sleeve.
→ Refer to the cable connection drawing on page 163 for
termination of the seven cable- pairs to terminal E201 in the
Transceiver Unit.
4 Run the cable from t he Transceiver Unit to the Motor
Control Unit mounted on the gantry.
5 Use the cable gland on the right-hand side in the Motor
Control Unit, and terminate the cable shielding in the cable
gland.
→ The cable shielding is described in figure 23 on page 65.
→ The interior of the Motor Control Unit is shown in figure
24.
6 Create a small cable slack inside the Motor Control Unit as
indicated in the figure.
7 Make the E301 connections in the Motor Control Unit
according to the cable connection drawing.
- Note that the shielding of each cable pair shall not be
connected in the Motor Control Unit.