Installation manual

Simrad SH80
64
851--164300 / C
7.5 Sonar room cabling
Introduction
All sonar room cabling must be performed as specified. The cable
numbers used to identify the cables in the figures and following
procedures are identical to those used in the cable plan and cable
overview table.
(CD5700B)
C15 C17 C18
Live Neutral
Ground
Figure 22
Transceiver Unit
cable connections
Note Due to the flexible shock mounting, all cables connected to the
Transceiver Unit must have appropriate slack to allow for
approximately 10 cm cabinet movement in all directions.
Cables
C17 - Motor control
This cable is connected between the Transceiver Unit and the
Motor Control Unit mounted on the Hull Unit. It is included with
the Transceiver Unit delivery with a length of 10 m.
Refer to page 163 for detailed information about the cable
terminations.
Observe the following procedure. To ensure correct operation, tick
off every item when the action has been carried out.
1 Use the cable gland on the left-hand side of the Transceiver
Unit.
The bottom of the Transceiver Unit is show n in figure 22.