Installation manual

Simrad SH80
22
851--164300 / C
Caution If, for any reason, it is necessary to move the circuit board or
components from the conductive service mat, they must be
placed in an approved anti-static transportation container (e.g.
static shielding bag) before transportation.
During installation and servicing, all electrical equipment
(soldering irons, test equipment etc.) must be earthed.
Temperature protection
If the unit must be protected against extremes of temperature, the
carton/crate must be lined on all walls, base and lid with 5 cm thick
polyurethane or polystyrene foam.
These units will be identified as delicate in the applicable
documentation.
The package must then be clearly marked:
Must not be transported or stored in temperatures
below -5 degrees Celsius.
Other units can normally be stored in temperatures between -30°C
and +70°C, though refer to the system’s Technical Specifications
document for details.
Transducers must not be stored in temperatures below -20°C.