Installation manual

Simrad SH80
134
851--164300 / C
11 TECHNICAL SPECIFICATIONS
11.1 Power specifications
SonarProcessorUnitMC70
Voltage:
- Nominal: 115 / 230 Vac, single phase (selectable)
- Deviation: 15 % of nominal voltage
- Transient : 20 % of nominal voltage, recover time 3 s
Power consumption: 150 VA
Frequency: 47 to 63 Hz
Transceiver Unit
Voltage:
- Nominal: 115 / 230 Vac, single phase (automatic)
- Deviation: 15 % of nominal voltage
- Transient : 20 % of nominal voltage, recover time 3 s
Power consumption: 600 VA
Frequency: 47 to 63 Hz
Note The default SH80 sonar system comprises a 230 Vac Transceiver
Unit. A 115 Vac version is optional.
Hull Unit
Voltage:
- Nominal: 230 / 380 / 440 Vac, 3-phase (selectable)
- Deviation, 230 Vac: 15 % of nominal voltage
- Deviation, 380 / 440 Vac: 340 to 485 Vac
- Transient : 20 % of nominal voltage, recover time 3 s
Power consumption: 3000 VA max
Frequency: 47 to 63 Hz
Sonar Interface Unit
Not applicable.
Display Unit
Refer to the documentation for the applicable unit.
11.2 Weights and dimensions
Operating Panel
Weight: Approximately 4 kg
Dimensions (WDH): 385x165x58mm
Refer to drawing 834-204688 on page 171.