Installation manual
Simrad SH80
130
851--164300 / C
10.7 Trawl system
Observe the following procedure to test the trawl system interface.
1 Access the I/O Setup menu.
→ A procedure for this is located on page 121.
2 Select Sensors in the I/O Setup menu, then Trawl System,
and f inally ITI or FS3300.
- Select ITI or FS3300 depending on the system you have
installed on your vessel.
3 Observe the Sensor Config submenu appears at the bottom
of the menu field.
4 Check that the settings in the Sensor Config submenu
correspond to your requirements for the serial line.
5 Press Close to exit the Sensor Config menu.
6 Check the trawl readouts as follows:
a Select the Setup menu.
b Press the Gear button to access the Gear submenu at the
bottom of the menu field.
c Select either of the Bottom Trawl or Pelagic Trawl
settings.
d Press the Edit button to access the Trawl Configuration
submenu
e Check that the different readouts in the submenu
corresponds to those from the connected trawl system.