10.6 Echo sounder
The SH80 Processor Unit can read the depth information from an
echo sounder on standard NMEA 0183 RS-232 serial line format.
Observe the following procedure to test the echo sounder interface.
1 Access the I/O Setup menu.
→ A procedure for this is located on page 121.
2 Select Sensors in the I/O Setup menu, then Echo sounder,
and f inally EchoNmea
3 Observe the Sensor Config submenu appears at the bottom
of the menu field.
4 Check that the settings in the Sensor Config submenu
correspond to your requirements for the serial line.
5 Press Close to exit the Sensor Config menu.
6 Select Bow up/Vertical mode.
7 Check that the depth readout in the Catch Data page
corresponds to the depth readout on the echo sounder.