Installation manual
Simrad SH80
122
851--164300 / C
13 Press Close to finish.
If you enter a wrong value and the sensor interface does not work,
you can change the parameters settings as many times as you wish.
The final settings you make are automatically saved when the
sonar system is switched off.
Serial line inspection
The Processor Unit contains an Object Inspector, where it is
possible to read the data of the connected serial line. This is a
valuable tool to check if the connections to the serial line are
working, and for checking the telegram format of the received
data.
Use the following procedure for viewing of the Object Inspector:
1 Select the Setup menu.
2 Presse Test... button to open the System test menu.
3 Press the Message Bar button, and observe the Message Bar
submenu appear s ath the bottom of the menu field.
4 Select Always on in the submenu.
- Observe the appearance of a small horizontal bar at the
bottom of the display. On the right hand side of the bar,
a few buttons display the number of warnings, errors and
alarms that are given.
Figure 41 The Message
Bar submenu at the
bottom of the menu field
5 Double-click on the message bar line.with the Object button
on the Operator Panel, or with right mouse button.
6 Observe the Object Inspector appears.