Installation manual

Start-up procedures
97
851-164300 / C
9.6 Checking the Operating Panel
Introduction
The simulated echoes makes it possible to test out most of the
operational functions without starting up the Transceiver Unit.
The layout of the Operating Panel is shown in figure 35
Figure 35 The Operating Panel
POWER
Up
Middle
Down
MAIN SW.
SYMBOL
Gain
H -
Range
H -
Gain
V -
Range
V -
Gain
H +
Range
H +
Gain
V +
Range
V +
MODE
Mode
1
GAIN
Mode
2
Mode
3
Mode
4
RANGE CURSOR
SelectMenu
View
Object
SONAR OPERATING PANEL
TILT
Manual
Auto
VARIOUS
Zoom
Record
Off
Centre
Position
Track
Manual
Target
Track
Auto
Search
TRAIN
(CD5377A / WMF / GIF)
SIMRAD
1
2 3
4
5
8
9
6
7
Functional test
Observe the following procedure to check a selection of the
operational functions.
Markers
1 Check the Target Marker.
a Use the trackball on the Operating Panel, and move the
cursor to the echo area.
b Press the Target Marker button (fi eld 2, top button).
c Check that a numbered triangle appears in the position of
the cursor.
2 Check the Ship Marker.
a Press the Ship Marker button (f ield 2, second button).
b Check if a square symbol appears at the ship’s symbol.