Installation manual
Simrad SD570 / Base version
6
851--160117 / B
j Writemeasuredthree--phasevoltagehere:.......................
j The hoist/lower motor is preconnected for 380V/440V
three--phase. If the measured three--phase voltage is
230V, the motor has to be reconnected. Remove the cover
forthe mainsconnectiononthe motor,andrefer tofigure
4 to link the motor connections to correspond to the
measured voltage.
j Adjust the release current of the motor overload switch
S301 according to the three--phase voltage:
230V: 2.4 A
380/440V: 1.6 A
j Remove the hand crank from its storage position.
j Set the motor overload switch to normal position by
pressing the black button marked ”1”.
j Set the hoisting/lowering switch S302 to LOWER.
j Check the training direction of the hoisting/lowering
motor by briefly pressing the hand crank safety switch
S303.
j Ifthetransducer shaftwashoisted,disconnectthe ship’s
three--phase mains fuses and change two of the
connectionstotheterminalsonthemotoroverloadswitch
S301. Reinsert the three--phase mains fuses.
j Set the hoisting/lowering switch S302 to STOP.
j Putthethe hand crankbacktoits storage position inthe
motor control unit.
j Checkifthere is sufficientspaceto lower thetransducer.
j Makesure thattheflexibletransducercables areinsuch
a position that the transducer can be lowered without
stretching or hard--bending the cables. Watch this
carefully during the next steps in this procedure.
j Set the hoisting/lowering switch S302 toLOWERforfull
lowering of the transducer. The lowering will
automatically stop when the top of the transducer shaft
hits the lower limit switch S305.
j Make a preliminary fastening of the flexible transducer
cables and watch the cables during the hoisting in the
next step.