1.2 Starting up the stand--by power supply
In order to start up the sonar units, the 24 VDC stand-by power
supply in the Transceiver Unit has to be started up first. Refer to
figure 1 and use the following procedure to start up the stand-by
power supply:
j Check that the mains input connector P201 on the front
of the power supply in the Transceiver Unit is
disconnected.
j Check that the switch S202 on the front of the power
supply is set to OFF (middle) position.
j Insert the mains fuses to the Transceiver Unit on the
ships mains switchboard.
j Measure the mains voltage supplied to the Transceiver
Unit.
Write the measured voltage here:...................VAC.
j Check if the voltage selector switches S201 on the power
supply and S203 on the HV power unit correspond to the
measured voltage (115V or 230V position).
j Reinsert the mains input connector P201 on the front of
the power supply.
j Check that the lamps L201 and L202 on the front of the
power supply illuminate.
j Checkthatthe small LED(LightEmitting Diode)forthe
+24Vstand--bypowerontheTransceiverInterfaceBoard
(TIB) illuminates (refer to indication on the front of the
power supply).
Now the 24VDC stand-by power is supplied both tothe HullUnit
and to the connector for the Sonar Control Unit.