Installation manual
Simrad SD570 / Base version
42
851--160116 / B
SPEED LINK SETTING
LK2 LK3 LK6
RS232 OUT IN OUT
RS422 OUT OUT IN
20 mA current loop IN OUT OUT
Do not insert the Control drawer unit before mentioned in a later
chapter.
7.4 Connecting other auxiliary equipment
If any other optional equipment is to be connected (echo
sounderortrawlsystem),refertotheappendixesinthismanual.
7.5 Remounting the electronic drawer unit
When the DIL switches and link settings for all auxiliary
equipment are correct, use the following procedure to remount
the electronic drawer unit:
j Remount the top cover on the drawer unit.
j Reconnect the two display cables.
j Lock the two display cables in the cable locker, and
arrange the cables as shown in figure 25. Enter the
drawer unit carefully into the cabinet, and check the
cables while entering the drawer. Note that the two
guiding pins at the inside of the rear wall in the cabinet
should enter the two guiding holes at the rear of the
drawer unit.
j Fasten the electronic drawer unit with the four 3mm
Allen screws on the front of the operator panel.