Installation manual

Introduction
27
851--160116 / B
6.4 The Hull Unit cabling
Connection of cable no. 6 in the motor control unit:
j Usethecableglandontheright--handside,andmakethe
termination of the main screen according to figure 15.
j Makeaslackonthecableinsidethemotorcontrolunitas
shown on figure 17, and make the connections to the
terminalE301accordingtotheinterconnectiondiagram.
Connection of cable no. 9 in the motor control unit:
j Use the cable gland on the left--hand side, and make the
termination of the cable screen in the cable gland.
j Make the connections of the three--phase mains power
directly to the motor overload switch S303 according to
theinterconnectiondiagram. Thegroundingwireshould
be connected to the ground terminal beside the overload
switch.
Figure 17 - Connections to the Hull Unit