Installation manual
Introduction
25
851--160116 / B
Figure 15 - Termination of the cable main screen
j Continue with cable no. 4 through the cable gland on the
righthandside (see figure14)andmake the termination
of the main screen according to figure 15. Make the
connections to terminal E201 according to the
interconnection diagram.
Note that the mains power connection to the Transceiver Unit can
be 115 VAC or 230 VAC. Use the following procedure for the
connection of the mains power:
j Pull out the mains input connector P201 on the power
supply in the Transceiver Unit. For location of the
connector, refer to figure 16.
j Set the mains voltage selector switch S201 on the Power
Supply and S203 on the HV Power Unit to correspond to
thecorrectmainsvoltage(115Vor230V),andreplacethe
switch lock to secure the switch in the correct position.
j Set the service switch S202 on the Power Supply to OFF
(middle) position.