6.3 The Transceiver Unit cabling
The cable numbers on figure 14 and in the following procedures
refer to the numbers on the cable plan and the interconnection
diagram.
Figure 14 - The cable connection in the bottom of the Transceiver
Unit
j All cable connections to the Transceiver Unit must have
aslackto allow theTransceiverUnitto move up to 10cm
because of the flexible shock mounting.
j Start the termination with cable no. 6. This because this
cable is connected to the lowest row of the terminals on
E201. Use the surplus of cable no. 4, or a similar type of
cable. Use the cable gland on the left hand side (refer to
figure 14) and terminate the main screen of the cable as
shown in figure 15. For termination of each cable pair
with screen, refer to the interconnection diagram. Use a
part of the enclosed cable sleeve on the screen of each
cable pair.