Installation manual

Simrad SD570 / Base version
22
851--160116 / B
6.2 The Sonar Control Unit cabling
All the cables to the Sonar Control Unit are to be plug connected
to the electronic drawer unit at the rear of the cabinet (see figure
13). The numbers on the figure refer to the cable numbers on the
cable plan.
Note ! In order to make service on the Sonar Control Unit, the cables must have
a slack so the electronic drawer unit can have all the cables connected
while it is outside the cabinet. This could be either by pulling it out from
the front, or by reconnecting the cables with the drawer at floor level.
Note that cable no. 4 (refer to figure 12) is delivered with a
standard length of 50 meters, and has a preconnected plug in the
Sonar Control Unit (wheelhouse) end.
j Pull cable no. 4 from the wheelhouse to the sonar room.
Note that the preconnected plug should be connected to
the Sonar Control Unit in the wheelhouse. Remember to
include the slack for service purpose.
j The mains power cable (3) may be connected to a normal
mains outlet in the wheelhouse. If the delivered cable
does not fit, put on a suitable connector. Note that the
mainspowertotheSonarControlUnitcanbe115VACor
230 VAC, and that this unit will automatically sense the
voltage.
The connection of the speed log (1) and the course gyro (2) will be
described in chapter 7.