Installation manual

Introduction
39
851--160117 / B
Enter the test hydrophone data for 57 kHz into table 1.
Hydrophone data Value Unit Example
Serial number Serial No. 1823860
Date of calibration* month/year 10/96
Calibrated at temperature °C 18°
Sensitivity as transmitter S
dB//1mPa/V
119.2
Sensistivity as receiver M
dB//1V/mPa
--208.9
M extension cable (0.7/10m)
dB//1V/mPa
0.7
M total = M + M extension
dB//1V/mPa
--209.6
Table 1 Test hydrophone data
For measurement of the source level in OMNI, use the following
menu settings:
RANGE......: 175M
MODE.......: BOW UP
PULSEFORM..: CW-NORMAL
TX POWER...: FULL
PINGSECTOR.: OMNI
Connect the hydrophone and TX ENABLE pulse to the
oscilloscope as shown in figure 14. Note that an optional cable
with connectors for the TX ENABLE pulse can be ordered from
Simrad.
As indicated in the figure, the distance between the transducer
and the hydrophone should be approximately 5 - 10 meters.