Installation manual

Simrad PI54
38
851-165187 / Rev.A
Cable gland installation for smaller vessels
This cable glands made of plastic is designed for those smaller
vessels that do not need to be classified.
(A) = Packing nut (bronze).
Ensure that you do not to
damage the transducer cable by
tightening the packing nut too
hard!
(B) = Rubber gasket
(C) = Plastic disk
(D) = Rubber gasket
(E) = Stuffing tube
(F) = Backing nut (bronze)
(G) = Backing washer (plastic)
(H) = O-ring 42.5 x 3.0 N
(I) = O-ring 39.5 x 3.0 N
(J) = Cable to the echo sounder
(or a junction box)
Stuffing tube hole diameter : 36 mm ±1.5 mm.
Apply ample amount of sealant between the backing washer (H)
and the hull plate.
The cable gland kit contains all the listed parts, except the
sealant.
Note: The two O-rings must be clean, in good condition and free of cuts
or other defects which could affect their water-tight integrity.
Splicing
If you need to cut the transducer cable, you must splice it
correctly.
Note: DO NOT solder the wires together with only electrical tape for
insulation, as this will result in electrical noise and reduced
operational performance.
To splice the cable, use a metal junction box. The chassis of the
junction box must be grounded, but the cable shielding must
NOT be connected to the junction box ground.