851-165187 / Rev.A
Transducer blister
With a transducer with circular housing, one recommended
installation method is by using a blister.
The transducer blister must be designed and manufactured by
the installation shipyard to fit the vessel’s sixe and hull shape.
Mounting and clamping rings
Circular transducers may be provided with mounting a nd
clamping rings, or with drawings to allow for local production
of these. The mounting ring is welded to the hole in the
transducer blister, while the clamping ring fits around the edge
of the transducer body. Bolts through the clamping ring into the
mounting ring will then secure the t ransducer between them.
Note that several transducers use direction guides to allow
correct mounting.
Inclination of the transducer face
Incline the transducer face approximately 1-2 degrees, so that
the flowing water meets it directly. This assures laminar water
flow.
Smooth surface
Mounting screws or bolts must not be extruding from the
transducer blister. Ensure that the surface of the transducer face,
the blister, the hull plating and putty around the transducer is as
even and smooth as possible. Obstructions on these surfaces will
create problems with turbulant flow.
Horizontal support bar
Large diameter transducers must be fitted with a horizontal
support bar. This bar can be secured to the mounting ring using
threaded rods.