Installation manual

Installation of sensor adapters
189
851-165187 / Rev.A
STEP 6: Measure the dimensions of the protective
cage legs
Using a yardstick bent at a ninety degree angle, measure the
length of standard 20 mm diameter bar stock necessary for the
apex of the protective cage to rise approximately 10 to 20 mm
over the sensor adapters.
Note: Mark the locations (on the doors) where the outboard protective
cage legs will be welded.
Cut and bent the bar stock accordingly.