Installation manual
Setup
169
851-165187 / Rev.A
Simrad 38/200 Combi W
Connect the transducer as described in the wiring diagram.
→ Simrad 38/200 Combi W (W814G), page 160
1 In the Echosunder setup dialogue, use the circular
selector pad to move the cursor (inverse video) to the
Transducer 1 / Type location.
2 Press the + button repeatedly until the setting reads
Simrad Combi W38&200.
3 Press the ENT key to save the setting and exit.
You can easily return to this setup page later, but DO NOT alter
the transducer setting unless you replace the transducer.
Caution: Due to its high efficiency, the output power on the PI54
is reduced when the 38/200 Combi W transducer is
chosen. If you choose an other transducer in the menu
when the 38/200 Combi W is connected, you may
damage the transducer beoynd repair.
Other transducers
Connect the transducer as described in the wiring diagram.